Latex-free dental dam (purple) is used for patients who have latex allergy.
Dental Dam should be disposed of in garbage. Single use only.
Instrument
Dental dam punch
Function
To punch holes in dental dam for each individual tooth
Characteristics
Designated hole size for each tooth for permanent dentition:
No. 5—Anchor tooth (largest)
No. 4—Molars
No. 3—Premolars
No. 2—Maxillary central and laterals, maxillary and mandibular cuspids
No. 1—Mandibular central and laterals (smallest)
Practice notes
The oral cavity is examined before holes are punched to accommodate the patient’s specific dentition.
A space of 3 to 3.5 mm is maintained between holes.
Dental Dam Punch must be cleaned, bagged individually or bagged/wrapped in a tray setup, and then sterilized. A chemical/steam indicator device should be included in the wrapping. Hinged instruments should be processed open and unlocked.
Instrument
Dental dam template
Function
To use as a guide for marking and punching holes in correct position on dental dam
Characteristics
Made of durable plastic
Has 32 dots that represent the adult dentition
Practice notes
The oral cavity is examined before holes are marked and punched to adjust positioning to the patient’s specific dentition.
The dental dam is placed on the template, and the points where holes should be punched are marked with a pen.
Dental Dam Template should be disinfected according to the manufacturer’s recommendation.
Instrument
Dental dam stamp
Function
To mark holes on dental dam
Characteristics
Has 32 dots that represent the adult dentition
Used as guide for punching holes in correct position
Practice note
The oral cavity is examined before holes are marked and punched to adjust positioning to the patient’s specific dentition.
Dental Dam Stamp should be disinfected according to the manufacturer’s recommendation.
Instrument
Dental dam forceps
Function