Modified Palatal Plate

Fig. 5.1

Palatal cortical bone density in adults and adolescents according to palatal area (From Han et al. [21])
In addition, Bernhart et al. [23] reported that the most suitable area in adults for implant placement in the palate was located 6–9 mm posterior to the incisive foramen and 3–6 mm paramedian to the suture. However, other study indicated that the area of high density in the cortical bone extended 15 mm posterior to the incisive foramen at the medial half of the measured area and 6 mm in the lateral half [21].
These studies supported Wehrbein’s [24] conclusion that the density of the median palate was high enough to support mini-implants. He also suggested that the reported 10 % failed micro-implants inserted in the palatal area [25, 26] may be attributed to factors other than bone density.

5.2.2 Palatal Bone Thickness

Several authors considered the palatal bone thickness a key factor of successful placement of TSADs [2730]. King et al. [29] evaluated the palatal bone volume for placement of implants in adolescents (mean age: 14.0 years) using computed tomography. Gracco et al. [31] also compared bone thickness in adults to that of adolescents using cone beam computed tomography (CBCT) and reported insignificant differences. Ryu et al. [32] compared the bone thickness of various palatal areas among early and late mixed dentition and permanent dentition using CBCT (Fig. 5.2).

A310907_1_En_5_Fig2_HTML.jpg
Fig. 5.2

Reference lines for evaluation of palatal bone thickness according to palatal area (From Ryu et al. [32])
The palatal bone might be significantly thin in the midsagittal area due to incomplete ossification of the midpalatal suture. Therefore, placement of TSADs in the paramedian palatal area has been recommended because of its thin keratinized soft tissue and sufficient cortical bone [28, 31, 3339].
The bone thickness decreased laterally and posteriorly in the paramedian area in adults [28, 32]. For adolescents, the anterior medial and lateral areas had the thickest palatal bone [32]. King et al. [29] demonstrated a sufficient vertical bone depth at 4 mm distal and 3 mm lateral to the incisive foramen to install a 3-mm-long implant in adolescents. In contrast, Gracco et al. [31] found no significant differences in the palatal bone thickness between adults and adolescents. However, their youngest group was over 10 years old, while Ryu et al. [32] focused on the adolescents and subdivided them into early mixed dentition (EMD) (mean age: 8.0 years) and late mixed dentition (LMD) groups (mean age: 11.5 years). The EMD group had significantly lower bone thickness than the two other groups, mainly in the anterior area. This inconsistency may be due to differences in methodology. Nevertheless, the bone thickness was greater in the anterior paramedian area than in the posterior one in all three groups of their study. This might be due to the difference in amounts of remodeling growth between the posterior and anterior parts [40].

5.2.3 Palatal Soft Tissue Thickness

The thickness of the palatal soft tissue has a great influence on the length of the miniscrew embedded in the bone. Therefore, it might be important to evaluate the soft tissue thickness of the palate before the installation of TSADs. Several methods have been applied to measure soft tissue thickness: direct measurement using a needle or periodontal probe [41, 42]; indirect measurement using CBCT [4346], which has a radiation exposure problem and limited resolution due to slice thickness; and direct measurement via ultrasonic device which is a noninvasive method that showed acceptable repeatability, reliability, and accuracy [4754].
Recently, the soft tissue thickness of midpalatal suture has been evaluated in cadavers [55]. It was thickest at a point 4 mm posterior from the incisive papilla (mean 2.93 mm) and decreased in more posterior areas, ranging from 0.90 to 1.01 mm. Lee et al. [56] showed thicker soft tissue thickness medially (1.80–2.21 mm) than that previous study [55] in the midpalatal region of the permanent dentition group. This difference may be due to shrinkage during the processing of the specimens [57, 58]. Table 5.1 shows comparison of palatal soft tissue thickness in different age groups according to their dental stage: late mixed, early permanent, and permanent dentitions (adopted from Lee et al. [56]).

Table 5.1

Comparison of palatal soft tissue thickness among late mixed, early permanent, and permanent dentitions (unit: mm)
 
Late mixed dentition (n = 42)
Early permanent dentition (n = 41)
Permanent dentition (n = 38)
 
 
Median
Middle
Lateral
p-valueb
Median
Middle
Lateral
p-valueb
Median
Middle
Lateral
p-valueb
p-valuec
Mean
SE
Mean
SE
Mean
SE
Mean
SE
Mean
SE
Mean
SE
Mean
SE
Mean
SE
Mean
SE
Anterior
1.79
0.41
2.05
0.40
2.39
0.39
< 0.0001
1.94
0.42
2.25
0.46
2.49
0.54
<0.0001
2.21
0.56
2.50
0.42
2.93
0.51
<0.0001
<0.001
Middle
1.83
0.69
2.04
0.66
2.38
0.61
1.83
0.70
2.20
0.72
2.47
0.67
1.80
0.69
2.70
0.84
3.19
0.75
Posterior
2.32
0.99
2.95
1.09
3.04
1.20
2.08
0.96
2.97
0.98
3.18
1.16
2.15
0.93
3.18
1.04
3.92
1.21
p-valuea
<0.0001
 
<0.0001
 
<0.0001
   
From Lee et al. [56]
Repeated measures ANOVA
Median represents the area between lines 0 and 4 mm lateral to the midpalatal suture; middle, between lines 4 and 8 mm; lateral, between lines 8 and 12 mm
Anterior represents the areas between lines 0–4, 4–8, and 8–12 mm posterior to lingual interdental papilla of incisors
Middle represents the areas between lines 12–16, 16–20, and 20–24 mm posterior to lingual interdental papilla of incisors
Posterior represents the areas between lines 24–28, 28–32, and 32–36 mm posterior to lingual interdental papilla of incisors
SE standard error
aThe significance level of the effect of the anteroposterior position in late mixed, early permanent, and permanent dentition groups
bThe significance level of the effect of the mediolateral position in late mixed, early permanent, and permanent dentition groups
cThe significance level of the comparison of the three groups
Vu et al. [59] have evaluated the soft tissue thickness on CBCT images and showed that the thinnest was over the midpalatal suture (1.22–1.27 mm), while the lateral area was the thickest (2.71–2.93 mm). Barriviera et al. [44] reported that the mucosal thickness of the higher region of the palate ranged from 3.13 to 4.51 mm. Song et al. [45] reported an increase in the soft tissue thickness of the area over the palatal slope from the anterior to the posterior (3.13–3.81 mm). These differences might be due to the different measurement sites and the ethnicity of the patients.
Wara-aswapati et al. [41] showed that the older (30–59 years old) population had thicker palatal masticatory mucosa than the younger (14–21 years old). However, this was not the case in other studies [49, 59]. Gender dimorphism was also controversial. Several studies reported no significant differences in the mucosal thickness between males and females [41, 59, 60]. Others found thinner palatal mucosal tissue in females [45, 53].

5.3 Clinical Application and Complications

5.3.1 Application of MPAP

The clinical applications and installation of the MPAP have been described in detail in several case reports [12, 13]. The MPAP should be adjusted on the dental cast to fit the shape of the patient’s palate. To achieve the best positioning of the MPAP, its arms should extend in the area between the first molar and second premolar or second deciduous molar. Enough space should be left between the arms and the palatal slopes.
Then, a silicon jig extending on the occlusal surfaces of the first molar and second premolar is fabricated to hold the plate firmly during placement and to keep even space between the arms and palatal soft tissue bilaterally.
At the placement appointment, local anesthesia is administrated; the jig-MPAP assembly should be placed by fitting the jig to the occlusal surfaces of the molars and premolars. And then, self-drilling mini-implants should be inserted through the screw tubes with an implant engine (30 RPM and less than 30 Ncm). After placement of three mini-implants, the jig is removed using a utility plier. Tightening of the mini-implant may be required after removal of the jig, as well as fine adjustment of the position of the arms. Then, a palatal bar with hooks is bonded to the first molars (Fig. 5.3). Immediately after placement, distalization can be initiated with elastics or NiTi closed coil springs.

A310907_1_En_5_Fig3_HTML.jpg
Fig. 5.3

(a) The Jig-MPAP assembly is placed in the patient’s mouth; (b) the assistant is holding the jig while the operator is inserting the miniscrews; (c) removal of the jig using a utility plier; (d) a palatal bar is bonded to the first molars to start distalization (From Kook et al. [13])

5.3.2 Complications

Altered Pronunciation

Recently, the speech perturbation and adaptation related to MPAP appliance over time has been evaluated [61]. A speech recording session of the alveolar, alveopalatal, and palatal sounds [t], [d], [s], [z], [n], [r], and [j] was made five times throughout treatment: T0, prior to PP placement; T1, just after the PP placement; T2, T3, T4, and T5, 1, 2, 3, and 4 weeks after MPAP placement, respectively. Acoustic analysis was performed using the Praat software (Paul Boersma and David Weenink, University of Amsterdam, Amsterdam, the Netherlands) to assess the pitch and the voice onset time (VOT) for each sound.
There were no significant changes in the pitch except for [r]; however, it changed back to normal after 1 week (Fig. 5.4). The sounds [t], [n], and [j] showed an increase in the VOT after MPAP placement followed by a decrease 1 week later. The VOT of [s] and [r] also increased after MPAP placement but decreased back to normal after 2 weeks (Fig. 5.5).

A310907_1_En_5_Fig4_HTML.jpg
Fig. 5.4

Pitch of different sounds over time
A310907_1_En_5_Fig5_HTML.jpg
Fig. 5.5

VOT of different sounds over time
It was concluded that MPAP might cause speech alteration in some patients. However, adaptation to the placement of MPAP appliance occurs within 1–2 weeks. Therefore, the clinician should advice patient and/or parents regarding the possible temporary effect of the MPAP appliance on speech prior to its placement.

Inflammation

Inflammation of the palatal soft tissue was commonly encountered in the early designs of the MPAP. This might have been due to the uneven positioning of the palatal arms during placement, the close contact between the plate and palatal soft tissue which results in impingement on the soft tissues due to micro-movement of the plate, and the difficulty in the maintenance of oral hygiene (Fig. 5.6).

A310907_1_En_5_Fig6_HTML.jpg
Fig. 5.6

Palatal soft tissue inflammation after placement of the early designs of the MPAP (From Kook et al. [13])

5.4 The Design Improvements of the MPAP

The design of the palatal plate has been modified several times to cope with the needs of the patient and the operator for easier and more accurate placement and less irritation to the tissues.

5.4.1 Screw Tubes

Tubes have been added to the screw holes to prevent or decrease soft tissue inflammation and overgrowth that might result from tissue impingement under the prototype of the MPAP. These tubes encountered the micro-movements of the plate under the distalization forces especially the torquing element. In addition, it might provide a plate-bone contact, which leads to reduction of the possibility of inducing inflammation on the soft tissue around the MPAP (Fig. 5.7).

A310907_1_En_5_Fig7_HTML.jpg
Fig. 5.7

Design improvement of the MPAP. (a) Prototype; (b) half tube extensions on the screw holes; (c) final design: screw tubes, angulated arms, and modified notches (From Kook et al. [13])

5.4.2 Angulated Arms

In some of the cases treated by the early design of the MPAP, the palatal bar becomes too close to the arms of the MPAP, and consequently, the distalization forces were decreased due to a very small range of action. This was corrected by manufacturing of a new palatal bar and in fewer cases by replacing the MPAP more posteriorly. However, this was perceived as undue waste of time and cost. Therefore, instead of having straight arms as in the prototype of the MPAP, the final design has been modified to have posteriorly angulated arms to increase the range of action (Fig. 5.7).

5.4.3 Modified Hooks (Notches)

Only gold members can continue reading. Log In or Register to continue

Stay updated, free dental videos. Join our Telegram channel

Dec 2, 2015 | Posted by in General Dentistry | Comments Off on Modified Palatal Plate

VIDEdental - Online dental courses

Get VIDEdental app for watching clinical videos