The purpose of this critical review is to list the sources of aerosol production during orthodontic standard procedure, analyze the constituent components of aerosol and their dependency on modes of grinding, the presence of water and type of bur, and suggest a method to minimize the quantity and detrimental characteristics of the particles comprising the solid matter of aerosol.
Minimization of water-spray syringe utilization for rinsing is suggested on bonding related procedures, while temporal conditions as represented by seasonal epidemics should be considered for the decision of intervention scheme provided as a preprocedural mouth rinse, in an attempt to reduce the load of aerosolized pathogens. In normal conditions, chlorhexidine 0.2%, preferably under elevated temperature state should be prioritized for reducing bacterial counts. In the presence of oxidation vulnerable viruses within the community, substitute strategies might be represented by the use of povidone iodine 0.2%-1%, or hydrogen peroxide 1%. After debonding, extensive material grinding, as well as aligner related attachment clean-up, should involve the use of carbide tungsten burs under water cooling conditions for cutting efficiency enhancement, duration restriction of the procedure, as well as reduction of aerosolized nanoparticles. In this respect, selection strategies of malocclusions eligible for aligner treatment should be reconsidered and future perspectives may entail careful and more restricted utilization of attachment grips. For more limited clean-up procedures, such as grinding of minimal amounts of adhesive remnants, or individualized bracket debonding in the course of treatment, hand-instruments for remnant removal might well represent an effective strategy. Efforts to minimize the use of rotary instrumentation in orthodontic settings might also lead the way for future solutions.
Measures of self-protection for the treatment team should never be neglected. Dressing gowns and facemasks with filter protection layers, appropriate ventilation and fresh air flow within the operating room comprise significant links to the overall picture of practice management. Risk management considerations should be constant, but also updated as new material applications come into play, while being grounded on the best available evidence.
Highlights
- •
Minimize the use of water-spray syringe during bonding related procedures.
- •
Consider prerinsing with mouthwash to reduce load of aerosolized pathogens.
- •
Use a carbide tungsten bur under water cooling conditions after debonding.
- •
Reconsider whether aligner treatment can be used.
- •
Risk management considerations should be constant and regularly updated.
The pandemic outbreak of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has had a large impact on the frontline of health care workers, and among those, on dentists and orthodontists. Besides the public health and economic burdens of the coronavirus disease 2019, it is now evident that its massive spread around the world has imposed great occupational challenges, with the implementation of routine dental services being at stake. The nature of the virus’ infectious route, with direct implication of airborne droplets in the form of aerosol, has revealed certain potential hazards underlying conventional and standard oral health care procedures. Orthodontic practices are not to be left aside. An aerosol is defined as a suspension system of solid or liquid particles in a gas. The term was introduced by Frederick G. Donnan to describe an aero-solution—clouds of microscopic particles in air. The various types of aerosol, classified according to physical form and how they were generated, include dust, fume, mist, smoke, and fog. Aerosol should be differentiated from solid particles staying airborne for some time in the air and the splatter of relatively large sized droplets of water generated by splashes in a dental setting, such as those produced by using the water syringe.
Aerosol-producing dental procedures, along with upcoming concerns, are not new to the dental discipline and at most, these concerns should not be selectively twisted, hampered, or emphasized under the light of the present pandemic or potential future endemics. They are effectively there since more than 20 years, and protective measures for dentists and clinic personnel should be prioritized in practice, irrespective of the presence of a pandemic, epidemic, normalized conditions, or otherwise. Furthermore, these concerns and protective measures should effectively be carried forward through advancements in technologies as well as evidence directed by new knowledge over the years. The current pandemic situation has boosted our thinking and endorsements on how to efficiently manage and minimize aerosol production in contemporary practice.
Evidently, common categories and burdens of orthodontics-related applications producing aerosol and/or airborne particulates are focusing on bonding and debonding strategies. The former involve application of water-spray practices in connection to enamel etching, before conditioning with bonding agents and bracket bonding; the latter pertain to enamel clean-up practices after removal of fixed appliances on completion of orthodontic treatment. Of late, in the line of debonding strategies, an additional procedure liable to aerosol generation has emerged in the clinical field; composite attachment removal after aligner therapy or possible attachment replacement and/or removal cycles during treatment with aligners should not be neglected. , This is particularly striking if one considers that most orthodontists and/or other clinicians utilizing aligner methods to straighten teeth and treat malocclusions have adopted wide application of these adjuncts in everyday practice. ,
With regard to bonding strategies, the conventional acid-etching stage may be employed with the use of a gel etchant of very thick consistency, a gel of lower viscosity, or a liquid etchant ( Fig 1 ). Implications for the first alternative are rather straightforward, as it might require a considerably higher pressure of water flow to be rinsed off, as well as a longer rinsing period; but practically, there is more. Very thick consistencies of gel essentially negate the action of acid for the amount of material not in contact with the enamel surface owing to limited wetting. Thus, the 2 other alternatives are often selected. However, high water pressure used generates splatter, which does not belong to the aerosol classification, but may too contribute to the contamination of the operatory. Water pressure is normally set at 40 PSI in the dental units, with existing air pressure at 80 PSI. The American Dental Association (ADA) has suggested testing of water squirt of more than 1.3 m (∼4 ft), as a practical measure of raised water pressure.
Regarding debonding strategies of fixed appliances, implication of rotary instruments used to remove remnants of composite compounds after fixed appliance removal, as well as utilization of water as cooling agent during handpiece usage form priority factors that should be considered. Cutting efficiency and aerosolized dust formation are also discussed.
This narrative article aims to discuss the hazards arising from routine orthodontic practices implicated to aerosol generation, sometimes on par with and following examples from standard dental procedures, and also to elucidate potential interventions or alterations of conventional orthodontic applications as an attempt to minimize substantial hazards or adverse effects. The narrative is built on 2 basic pillars regarding aerosol generation; the microbiologic on one side, and particulate production and toxicity related implications on the other.
Microbiologic Considerations and Bio-aerosols
The pathogenic pervasiveness of dental aerosol rests in its dependence on the concentration of bacterium or virus load in compressed air, or water-spray spatter mixed-up with tooth material, plaque, blood, calculus, and saliva debris that are theoretically and practically produced during routine dental practice, which makes use of an intraoral service handpiece. As such, orthodontic practices fall within the range of these procedures, seemingly within a more limited extent, but it is important that they are not neglected. The presence of dental unit waterlines (DUWLs) microbiota has also been considered an additional intriguing factor, especially because pathogens get carried forward through the water supply system directly to the handpiece in use. When coolants are used during service, the interaction of the cooling agent with fluids and debris produced within the oral environment as a result of composite or tooth grinding practices or use of ultrasonic scaling is present, and inductively, it may be detected in air-suspended particles and aerosol. The Centers for Disease Control and Prevention has established a safety maximum level of colony forming units (CFUs) emitted and detected in the air at the threshold of 500 CFUs per mL as a result of dental handpiece and water and/or air supply instrumentation usage, excluding coliform bacteria for nonsurgical procedures. These levels are liable to reduction when immunocompromised patients are in chair, and are lowered to 200 CFUs per mL. Evaluation of pathogen levels may be done through simple commercially available test strips or kits. In addition, air and/or water related dental instrumentation (handpiece, spray syringe, and/or ultrasonic scaler) in direct usage to patients’ oral cavity should be flushed and pseudotested for 2 minutes at the start of each day, as well as for 30 seconds between patients.
A recent systematic review on bioaerosols in dental environment has pinpointed the presence of 38 types of micro-organisms, including 19 bacteria and 23 fungal genera, indicating a high variety of a range of species, whereas it was interesting that none of the included articles reported on the presence of viruses or parasites; seemingly, this is not linked to their absence from air-suspended droplets, but rather to the line of focus of the primary studies, partially in favor of the abundance and commonness of the former pathogens and their easier and nonspecific detection through wide air sampling techniques. A mean bacterial load range of 1 to 3.9 CFUs in logarithmic scale has been reported after procedural produced aerosol, while the most eminent load has been reported in the range of 1.5 meters from the oral cavity, even higher compared with closer distance measures such as that of 1 meter from the patient. Fusobacterium family pathogens have been identified in aerosols produced after ultrasonic scaling in practice through checkerboard DNA–DNA hybridization techniques. , Of the family, Fusobacterium nucleatum has been identified as a bacterium related to pathologic, ophthalmic, and respiratory implications, while also inductive of cellular apoptosis in vivo. , In addition, it has been reported as related to the launch and progression of periodontitis, or as attenuating attribute of gingival fibroblast mesenchymal cell proliferation. However, the results of checkerboard hybridization techniques should be interpreted with caution as per the exact bacteria species eligible for identification, because such practices are close ended, checked in preselected DNA-probe panels and other pathogens not prespecified might be present within droplet spatters as well. Nonetheless, studies assessing mostly periodontal pathogens have identified an increased prevalence of species belonging to the so-called orange complex in aerosols generated during usage of ultrasonic scaler. , These mostly pertained to Campylobacter rectus , Prevotella intermedia, and others, including F. periodonticum in addition to F. nucleatum . Apart from directly exposed aerosolized bacteria, another potential contamination source within dental offices or in hospital based dental units has been identified and special attention has been placed to the presence of Legionella pneumophilla as well as Pseudomonas spp in DUWLs. , These might well serve as routes of infection for patients and/or dental personnel indirectly and via droplet suspension after aerosol-generating handpiece or water and/or spray syringe usage. Other sources of L. pneumophilla constitute air-conditioning systems or cooling towers within dental settings. , Interestingly, the novel SARS-CoV-2 has also been lately reported to demonstrate capacity of emanation via the airflow of air-conditioning units in business environments.
An array of clinical studies, since more than 25 years and until recently, have attempted to identify effective methods of reducing pathogen load stemming from aerosol forming procedures in dental settings ( Fig 2 ). The vast majority have studied in-service utilization of ultrasonic scaling, whereas some have reported on orthodontic related strategies of debonding procedures, or other dental prophylaxis or restorative procedures. , Largescale efforts have been lately endorsed to collectively appraise all available evidence and provide justifiable ranking of the efficiency of these methods. , The most prevalent recorded approaches were preprocedural mouth rinse using a wide variety of potentially antimicrobial agents, such as, chlorhexidine (CHX) 0.12%, CHX 0.2% or tempered CHX 0.2%, cetylpiridinium chloride 0.05%, povidone iodine (PI) 1%, chlorine dioxide, herbal-based agents, or others pertaining to ozone irrigation, use of high volume evacuators and/or dental isolation systems, or agents added to DUWLs to reduce the load. , , ,
Evidence from a study on bacterial load during orthodontic procedures comparing bracket debonding followed by enamel clean-up with high-speed handpiece and water cooling versus standard orthodontic care involving archwire and/or ligature change, and replacing procedures, highlighted the increased pathogenic state of aerosols produced by the former, with a mean difference of 49.2 (95% CI, 19.4–79.0) in total CFUs. This highlights the exposure hazards of orthodontists related to certain orthodontic procedures in practice and draws attention to additional prophylactic measures to be selectively taken within the dental operating office. Effectively, bacterial load in aerosol in the dental and/or orthodontic cabinet has shown to be significantly raised immediately within 5 min of service for an aerosol-generating procedure, including enamel clean-up.
Further evidence on microbiologic assessment of aerosol produced after debonding of fixed orthodontic appliances and during composite clean-up has elucidated the increased potential of aerosolized particles, particularly those with aerodynamic diameters of 50 μm or less, to surpass the respiratory barriers and invade deep into the lungs, along with pathogen contaminants. , Bioaerosol infiltration has been detected in simulation studies all the way to the respiratory tree from the pharynx to the bronchial alveoli of the lungs. Although decreased particulate size seems to exhibit increased potential to penetrate deep into the lungs, the viability of pathogens has been shown to simultaneously decrease, also impacting biodiversity at the deep respiratory levels. ,
Use of preprocedural mouthrinse with CHX of either 0.12% or 0.2% concentration has been identified by individual studies as an important decontaminating agent contributing to identification of decreased bacterial amounts of infected aerosol; latest data coming from an endorsement to compare all direct and indirect evidence from examined interventions (mouth rinses, evacuators, decontamination of DUWLs, and others) across studies and within dental settings, has revealed this supremacy of preprocedural chlorhexidine mouthrinse over other measures for 30 s to 1 min, but also with documented prevailing of tempered (47°C) CHX 0.2%. , , , , , , Tempered CHX solution at 47°C, has been reported to offer increased anti-microbiologic action against bacteria of the human dental plaque, while also preserving adverse effects on tooth and pulp vitality to the minimum. The increase in bacterial kill rate has been determined to reach as high as 25% surplus, while to avoid storage contamination with toxic compounds such as p-chloroaniline, freshly made CHX solutions should undergo heating. As this measure might be potentially considered impractical for the routine management of clinical practice, it might still be the treatment of choice for highly prone to aerosol induction procedures, with water cooling involvement; other solutions could also be considered for more conservative procedures. Among the priority treatments of choice and apart from CHX solutions (either tempered or nontempered), PI 1% has also been considered a viable alternative. ,
Aforementioned documented evidence originates, as discussed, primarily from ultrasonic scaling clinical studies, randomized in most cases, while total bacterial count in generated aerosol has been the outcome of interest, leaving virus load aside. Extrapolation to other potentially producing aerosolized compounds procedures, however, seems reasonable within a dental cabinet setting and certain orthodontic procedures, such as fixed appliance debonding, may benefit from such measures.
At present and in the middle of SARS-CoV-2 pandemic mid-2020, there is no evidence from clinical trials on the effectiveness of interventions taken preprocedurally in dental offices against viral load in air-suspended droplets or aerosols. However, it would be reasonable to assume that mouth rinses or irrigates with proven capacity to interact with viral molecules and its cellular membranes might prove beneficial. On the basis of the oxidative action of such agents against the lipid membrane of coronaviruses, latest reports as well as primary guidelines of the National Health Commission by the People’s Republic of China on measures against SARS-CoV-2, have indicated a decreased effectiveness of chlorhexidine as a measure of choice, mostly because of the lack of oxidative action, while use of hydrogen peroxide 1%, or PI 0.2% to 1% appear more realistic as effective alternatives. Oxidative agents act directly on the lipid shell membrane of the virus and destroy cellular components. In particular, PI action is enhanced by the slow and gradual release of iodine as carried by the povidone vehicle, while any adverse effects of iodine are reduced, allowing for a toxicity-free simultaneous interaction. Based on the absence of clinical trials in the field of virus load of aerosols, latest calls have emerged and suggest the use of flavonoids or cyclodextrine agents to fight or attenuate SARS-CoV-2 infection through saliva expectorations or spatters secretions. However, their effectiveness remains to be tested.
Composite Grinding and Particulate Production
Cutting instrumentation
Composite grinding and particulate production during handpiece instrumentation usage in routine dental practice has been considered an additional source of potentially hazardous concern for dentists and orthodontists in general, but also in particular in the middle of a pandemic of a novel SARS-CoV-2, with unprecedented impact worldwide.
An initial notion before any consideration of produced aerosolized dust is cutting efficiency and types of dental rotary instruments that might effectively reduce grinding duration. Knowledge on the topic may largely be attributed to the extensive research and work on this field by A.J. von Fraunhofer et al.
Type of cutting bur and mode of action
First, discrimination between commonly used burs in terms of cutting mechanism is discussed, roughly between 2 of the most prevalent cutting instruments in use, tungsten carbide and diamond burs. The tungsten carbide burs differ from diamond burs, as they are considered to achieve material removal through a flow-dependent fracture process (plastic flow), occurring as a result of elevated shear forces between the carbide blades and the material surface; this makes them rotary instruments of choice for cutting ductile substrates including composites, dentin, or metals. Dissimilarly, diamond cutting burs induce brittle fracture of substrates, functioning by creating grooves and making use of dislocation motion and subsequent radial flow of the material, ultimately leading to propagation of cracks by the generated tensile stresses produced and chip formation. Evidently, diamond burs are mostly efficient for ceramics or enamel surface. Latest innovations for adhesive removal after completion of orthodontic treatment, entail the use of fiber-glass or fiber-reinforced composite burs, which have been reported to exhibit a potential for reduced enamel surface roughness on enamel clean-up, compared with standard carbides. , However, no data is currently available with respect to the effect of these cutting burs on particulate composite dust dynamic.
Moreover, water supplementation and spray patterns of the handpiece during tooth or material grinding, apart from the straightforward effect on preservation of temperature within tooth and pulpal tolerable standards, have also been implicated as a medium for achieving efficiency during the cutting procedure. Water spray during tooth preparation within a proximal value of 40 mL/min room temperature has been considered reasonable for avoiding pulp interactions. In reality, water or other lubrication medium has been considered to play a significant role in cutting efficiency following Reynold’s hydrodynamic lubrication theory.
In particular, across dental setting environments where standard and known length and material cutting instruments are used for commonly used 400,000 rpm bur rotation speed, it appears unlikely that effects of dynamic viscosity of coolant media may be significant. Testing across water coolant, alcohol (1%) as well as glycerol (2%) solution has revealed comparable effects.
Further, water application as coolant usage during material grinding in practice, including enamel clean-up from bonding remnants after orthodontic treatment, offer a thin line layer of interproximal matter between the carbide and material interface. This is considered to induce surface adsorption alterations in the substrate material after reduction of the surface-free energy, produced by changes in the strength of association of the interatomic bounds between interactive entities, thus resulting to surface hardness changes. To this respect, and as discussed above, cutting with carbide burs in ductile substrates such as resin remnants after debonding of fixed appliances or bonded attachment removal after or during aligner therapy, shall be advantaged, in terms of cutting efficiency, by water supplementation targeted directly to the carbide-composite interface, in the following manner: initial groove formation after bur application is generated, followed by lateral displacement of the substrate, pilling-up material dislocation, and crack propagation, resulting in chip formation. The described procedure broadly follows the original work of Rehbinder et al back in 1940s, who suggested that chemically-induced surface hardness changes bear the potential to increase drilling efficiency of the cutting tool in mining settings with aqueous surfactant solutions, within a range of 30%-50%. Gain is 2-fold, with subsequent extrapolation to orthodontic and dental practice: faster advancement of the bur into the substrate and decreased demand for heavy load application in practice, thus reduction in operating time and total amount of aerosol production.
Material substrate, composite dust, and aerosol
Resin composites are known to possess a wide range of applications in dentistry, with orthodontics usage in bonding procedures of both fixed appliances as well as treatment with aligners and attachment adjuncts being in the spotlight. Normal composite composition comprises of the resin matrix (usually represented by bisphenol-A [BPA] diglycidyl dimethacrylate, triethylene glycol dimethacrylate, and ethoxylated BPA glycol dimethacrylate), the inorganic filler compounds as well as a coupling agent to guarantee bonding between the two. Filler compounds usually fall below 0.4 μm and may serve in a wide range of particulate sizes and even fall within the nano-range. , Orthodontic adhesives have also been considered to acquire quartz-type filler particles as well. Heavy metal oxides are preferred, namely barium, strontium, zinc, aluminum, or zirconium, while their primary service remains to offer enhanced physical and mechanical properties to the material, including polymerization shrinkage water sorption and solubility, radiopacity, and reduction of biodegradation in-service.
During debonding strategies, but also lately increasingly during attachment removal in the course of and/or after the end of aligner treatment with thermoplastic-type devices, breakdown of the bulk of composites takes place, with material micro- and/or nano-fragments being aerosolized. These particulates bear the aerodynamic potential to surpass the respiratory fraction barriers and natural defense mechanisms of the clinician, patient and office personnel and find their way deep into the lungs. ,
A foremost effort to provide evidence in the field of aerosolized composite compounds in dental settings, has been mainly initiated and driven by 2 separately working groups in Leuven, Belgium, and Bristol in the United Kingdom, in essence after simulation in clinical conditions. , , Evidently, aerosols comprising of particles lower than 10 μm or 2.5 μm (PM 10 or PM 2.5 , particulate matter) are gaining attention due to their potential to enter the respiratory tract; interestingly, even smaller particulates within the range of dozens of nanometers (<100 nm) have been associated with an increased dynamic to surpass the primary boundaries of the respiratory system and reach deepest levels of the terminal epithelial bronchioles of the lungs because of their increased surface to volume ratio, offering an amplified reactive potential when in interaction with cellular interfaces.
Several studies have investigated the content compounds of composite dust produced in aerosols in dental and orthodontic setting, and it has been claimed that percentage and concentration of nano-sized identified filler particles in the aerosols might be related to the original filler content of the composites. However, this is far from the case, because all types of composites, irrespective of filler size, have been reported to exhibit significant amounts of nanoparticles within the range of 38-70 nm during grinding and clean-up. , , , In particular, surface friction and heating shock during composite grinding results to matrix decomposition of the substrate, aging, C=C conversion of bonds on surface, and ultimately production of respirable composite dust.
Wet or dry conditions
Apart from water supplementation contribution to the cutting efficiency of grinding tools on the composite substrate during debonding, thus offering minimization of (bio)-aerosol production duration, the effect of water as per emanation, and generation of airborne dust has been disputed, however, with scarce evidence from few research efforts, across variable settings. In essence, a recent study inspected the effect of water cooling in slow-handpiece usage on bulk composite sticks containing an array of filler sizes under simulated conditions of dry and wet grinding. Their work suggested consistent findings for all types of composites, which demonstrated a significant reduction in the number of detected nanoparticles being released when water spray was in-service (5.6 × 10 5 – 13.7 × 10 5 numbers per cubic centimeter), denoting a half-pace reduction, compared with dry settings. Interestingly though, both dry and wet grinding alternatives produced high numbers of nano-sized particulates being aerosolized overall. The highest amounts have been detected during the last minute of grinding, reaching levels of approximately 33 × 10 5 numbers per cubic centimeter. Particulate agglomeration has been considered to occur across time, thus contributing in increasing average particulate diameter, overall. To this respect, under water usage conditions, airborne generated nanoparticles have been considered particularly prone to being trapped within water droplets, resulting in increased matter sizes, which are less likely to achieve penetration of the epithelial bronchial barriers and find their way to the lungs.
The aforementioned conditions and settings could be considered as vastly resembling to the bulk attachment material removal during orthodontic treatment with aligners. As previously discussed, aligner usage for treatment of malocclusions currently involves increasingly frequent adoption of composite grips bonded to tooth enamel, sometimes more than 1 per tooth, as attachments of various sizes and shapes, with nonnegligible dimensions, varying within the range of 2-5 mm and also width or thickness that may exceed 1 mm. , These adjuncts target to the achievement of modes of tooth movement, either rotational or translational, within all 3 planes of space, which would otherwise be non- manageable with the early phase plain thermoplastic aligner usage, that do not necessitate enamel involvement. This compares to the thin layer of composites used as a layer of “sandwich-type” pattern between the bracket base and the enamel surface in a conventional case fixed appliance treatment, with an average estimated thickness of 150 to 250 μm; one may evidently cognize that the bulk and thickness of the attachment grips in aligner therapy is implicated in 2 conditions: first, the occurrence of an excessive amount of composite polymerized material within the oral cavity, allowing for the potential risk of BPA release or monomer leaching, depending on the number and shape or size; second, grinding procedures for attachment removal may prove extremely exhaustive and timely, bearing an increasing risk of excessive production of aerosolized composite dust. , , ,
Handpiece role
Furthermore, an earlier report on human extracted teeth and subsequent simulated bracket removal and enamel clean-up, has examined the effect of handpiece, water coolant, and high volume evacuator as well as surgical facemask, on the amount of particulate production and particle concentration during composite grinding after debonding; however, the baseline effect of handpiece was variable, because slow-speed handpiece was used in absence of water coolant, whereas high-speed handpiece only under water-spray emission. Findings structured on nonparametric data revealed a significantly higher concentration of airborne particulates under wet conditions and the use of high-speed instrumentation. In addition, use of facemask appeared considerably effective, contributing to the reduction of the detected concentration, while high volume evacuator was not identified as a critical parameter in this respect. To date, there is no further evidence on the direct crude effect of handpiece variation and rotary instrumentation speed with regard to airborne particulate generation, under otherwise comparable conditions.
Cytotoxicity and Estrogenicity of aerosolized particulates
Following research about cytotoxicity and xenoestrogenic effects of BPA and/or monomer release of adhesive compounds within the oral cavity, airborne particulates produced during grinding of composites after fixed appliance removal or aligner’s attachment elimination, are seemingly a potential source of similar concerns. , A mild but gradual reduction of human bronchial epithelial cell viability in laboratory conditions has been documented, giving rise to speculations on the reactive dynamic of such particulates. , Composite filler particles and matrix composition of restorative adhesives did not appear to play a role. Interestingly, the latest report encompassing orthodontic adhesive material evaluation at grinding stages after simulated conventional orthodontic treatment, pinpointed the aptitude of aerosolized particles of adhesives comprising of quartz-type fillers to demonstrate disrupting effects on interacting cell membrane integrity and cellular viability, while also to intervene with cellular growth potential of epithelial bronchial populations at an early stage. These effects are probably related to the size and shape of such fillers’ configuration, following the increased surface to volume ratio they present.
Related evidence on orthodontic adhesives comes also from the assessment of in vitro estrogenicity of orthodontic composited ground under simulated bonding-debonding settings. Estrogenic effects appear as a result of residual monomer release (BPA), which follows action as an endocrine disruptor because of the very similar structure with beta-estradiol. , Under the use of highspeed handpiece without water-spray, eluents containing airborne particulates, after grinding different types of adhesives (ie, chemically or light-cured), have shown an increased proliferating capacity on MCF-7 breast cancer cells in vitro.
Such findings are of particular interest and raise considerable awareness when it comes to the large-scale removal of attachment grips implicated in aligner therapy. The bulkiness and volume of these adjuncts evidently requires a great amount of grinding efforts and intraoral cutting instrumentation service. It is therefore likely that a significant amount of heat influx occurs first at the surface of the composite substrate if not substantially cooled, resulting in heat shock of the matrix. Resultant effects on chemical decomposition of the produced aerosolized dust with further implications on monomer release and BPA diglycidyl dimethacrylate compounds might be alarming. , Thus, broad and time-consuming composite removal, as required in extensive removal of attachments, with no water cooling in-service, should largely be avoided, while further research in the field is critical to detect specific effects of water supplementation to the emanation of monomer and other potentially estrogenic compounds.
Implications and recommendations for clinical practice
Direction of measures taken to minimize effects of aerosol production in orthodontic practice should target in 2 basic routes: bonding and debonding procedures, in essence those are interconnected ( Table ).