A pilot study to assess the feasibility and accuracy of using haptic technology to occlude digital dental models

Abstract

Objectives

The use of haptic technology as an adjunct to clinical teaching is well documented in medicine and dentistry. However its application in clinical patient care is less well documented. The aim of this pilot study was to determine the feasibility and accuracy of using a haptic device to determine the occlusion of virtual dental models.

Methods

The non-occluded digital models of 20 pre-treatment individuals were chosen from the database of Faculty of Dentistry, The University of Hong Kong. Following minimal training with the haptic device (Geomagic ® Touch™), the upper model was occluded with the lower model until a stable occlusion was achieved. Seven landmarks were placed on each of the corners of the original and haptically aligned upper model bases. The absolute distance between the landmarks was calculated. Intra- and inter-operator errors were assessed.

Results

The absolute distance between the 7 landmarks for each original and corresponding haptically aligned model was 0.54 ± 0.40 mm in the x -direction (lateral), 0.73 ± 0.63 mm in the y -direction (anterior–posterior) and 0.55 ± 0.48 mm in the z -direction (inferior–superior).

Conclusion

Based on initial collision detection to prevent interpenetration of the upper and lower digital model surfaces, and contact form resistance during contact, it is possible to use a haptic device to occlude digital study models.

Clinical Significance

The use of 3D digital study models is routine, but new problems arise, such as the lack of “touch” in a virtual environment. Occluding study models requires the sense of touch. For the first time, using haptic technology, it is possible to occlude digital study models in a virtual environment.

Introduction

Conventional plaster study models have been used in dentistry for centuries. Over the last decade there has been a drive to replace them with digital study models to overcome common problems; including storage space issues, loss, damage or degradation of the plaster models over time .

The common methods of obtaining digital study models include surface scanning the plaster model or impression , direct intra-oral scanning and volumetric scanning of plaster models or impressions with the ability to produce surface images at a later stage if necessary. Digital dental models have been used for crown and bridge fabrication , orthodontic treatment planning and appliance fabrication , implant planning and stent production , partial denture frame work manufacture , orthognathic surgery planning and final wafer fabrication . The majority of these procedures can be performed on models of a single arch. For orthodontic aligners or pre-fabricated custom orthodontic appliances the entire upper and lower arches are imaged out of occlusion to capture all the occlusal detail and then in occlusion to obtain the correct inter-occlusal relationship. The individual teeth are segmented and moved into the desired position without being able to assess the subsequent inter-occlusal consequences. During crown and bridge fabrication often only a localised region of the arch constituting the preparation and adjacent teeth is imaged, together with the corresponding region of the opposing arch. This enables the CAD/CAM crown to be designed with the correct static inter-occlusal relationship. At present it is not possible to “feel” the final occlusion following any “virtual laboratory work” fabricated on the virtual dental models.

A possible solution is to use “haptic” technology. Haptic technology or haptics, is tactile feedback technology which recreates the sense of touch by applying forces, vibrations, or motions to the user through a haptic device. Haptics has been used in dentistry for training including cavity preparation , implant placement and surgical simulators . The outcome of its use has mainly been assessed from an educational perspective as an adjunct or alterative to actual “live” clinical exposure . Currently physical dental models are used routinely in dentistry. By using 3D imaging the visual topological characteristics are maintained but the physical characteristics are lost. These can be re-established by printing the model and going full circle or using haptic technology and remaining in the virtual environment.

One of the simplest and most common tasks is to occlude physical study models. Now that 3D digital models are nearly routine practice, is the same possible? Therefore, the aim of this paper is to determine the feasibility and accuracy of using a haptic device to determine the occlusion of dental models and discuss possible future uses. The null hypothesis tested was that there were no statistical significance differences between the mean distance of the landmarks in the x (medio-lateral), y (anterior–posterior) and z (inferior–superior) directions, on the original model, and on the haptically aligned upper models.

Materials and methods

Approval was granted by the Institutional Review Board (IRB) of The University of Hong Kong and Hospital Authority Hong Kong West Cluster (UW11-385) to access this retrospective data, which formed part of a larger cohort study. The orthodontic plaster models were selected from the Faculty of Dentistry, The University of Hong Kong. Only pre-treatment plaster models which could be hand articulated into a single position without any instability e.g. no anterior open bite were included. The correct occlusion had been determined by the inter-occlusal registration or bite that was taken during the clinical examination and record taking session. In total 20 sets of plaster models were selected and the patient hospital numbers recorded. The patient identifier was used to download the corresponding digital models and all images were anonymous and de-identified prior to use.

The digital models had been commercially produced by laser scanning the plaster models using the following process (Modern Dental Laboratory, Cheung Sha Wan, Kowloon, Hong Kong). All dento-alveloar surfaces of the individual upper and lower models were individually scanned together with the full buccal surfaces of the teeth with the models in occlusion (3Shape, Copenhagen, Denmark). The bases of the plaster models had been previous trimmed according to the bite taken at the clinical appointment; this ensured the correct occlusal relationship during scanning. Following scanning the upper and lower models were automatically aligned to the image of the buccal teeth in occlusion (OrthoCAD ® , Cadent, Carlstadt, NJ). New “orthodontically trimmed digital bases” were added to the models. Following scanning, the occlusal contacts of the upper and lower model were assessed using a colour error as well as being visually compared to the original plaster model. The final models were saved as STL files and stored.

Each set of digital study models was imported into VRMesh (VirtualGrid Company, Seattle City, U.S.A.) and decimated by 50% to reduce the number of triangles and enable faster processing ( Fig. 1 A). The original base of the upper model was removed leaving only the teeth and alveolar regions. The lower model was not altered and remained in the same 3D space. The upper model was moved away from the lower model, its orientation changed, ( Fig. 1 B) and then re-saved in its new position in 3D space.

Fig. 1
(A) Final original digital models in occlusion. (B) Upper and lower digital models with virtual bases removed leaving only the teeth and alveolar regions. Removing the bases ensured there were no visible indications for the upper model position.

A prototype system was implemented on a desktop PC with an Intel ® CoreTM i7-3930K CPU and an NVIDIA GeForce GTX 680 display card (Santa Clara, California) connecting the Geomagic ® Touch™ (3D Systems, Rock Hill, South Carolina) haptic device (formerly Sensable Phantom Omni). The Geomagic ® Touch™ provided 6 degrees of freedom (DOF) input and 3DOF force feedback output ( Fig. 2 ). The graphics rendering, and haptic rendering components worked in parallel. The upper dental model was manipulated through the stylus of the haptic device. As haptic interaction is not routine in clinical practice, the operator (BSK) underwent a training session based on fitting 3D shapes into each other using the haptic device. This was followed by haptically aligning 7 training sets of digital models not included in the main study. During the training, once the upper study model was manipulated into the correct position, it turned green. This provided the operator with immediate confirmation of the model position; this function was disabled during the main study.

Fig. 2
Haptic prototype system in use during training session. (A) Pen shaped haptic device (Geomagic ® Touch™ haptic device, formerly Sensable Phantom Omni).

For each set of models, the lower digital model was imported into the prototype system together with the upper model. Using the haptic device the upper model was placed onto the lower model and moved until the operator had a stable occlusion. This was tested by gently moving the haptic device in all three planes of space and feeling resistance i.e. the force feedback indicated the models were “locked” into occlusion. The upper model was then saved in its new 3D space as an STL file.

For each set of digital models, the haptically aligned upper model (teeth and alveolus only), full lower model and the corresponding original upper model were imported into VRMesh. The original upper model was then aligned to the haptically aligned upper model, which remained static. These two models are the same model but the haptically aligned model has no base; the haptically aligned upper model was deleted leaving the original model with base in its new position, this will still be referred to as the haptically aligned model. This model was then saved in STL format ( Fig. 3 ).

Fig. 3
(A) Front view of original digital models in occlusion (grey) and same upper model following haptic alignment (red) with replacement of original virtual base. (B) View from above showing original model (grey) and haptically aligned (red) model bases do not exactly align. (C) Occlusal view of upper model showing original model (grey) and haptically aligned (red) model do not exactly align.(For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)

Operator error

Intra-operator

To determine the intra-operator error 8 sets of models were chosen at random from the original set of 20 models and re-occluded using the 3 DoF haptic system, and re-analysed. The internal consistency of the data for the x , y and z co-ordinates was tested individually using Cronbach’s alpha and the intraclass correlation coefficient (ICC) was used to assess the reproducibility of the method.

Inter-operator

To determine the inter-operator error, 7 additional sets of models were chosen at random and occluded using the 3 DoF haptic system, by a clinician and a non-clinician (student in Computing Science), and analysed. A paired student t -test was used to compare the differences in mean absolute distances of the seven landmarks between the original model and haptically aligned model for the clinician and the non-clinician ( p < 0.05).

Analysis

For each individual, the original upper and lower digital study models were imported in DiView (Dimensional Imaging, Hillington, Glasgow) and 7 landmarks were placed on each of the corners of the upper model base ( Fig. 4 ). The x , y and z co-ordinates of these landmarks were saved. The same individuals haptically aligned upper model, and unaltered lower model, were also imported into DiView. Since they occupied the same 3D space and the lower model had not moved, both lower models were exactly aligned. The same 7 landmarks were placed on each of the corners of the haptically aligned upper model and the x , y and z co-ordinates saved. If the haptically aligned model was in the correct place, both upper models would be perfectly superimposed; any discrepancy in the landmark co-ordinates would provide a measure of the error represented by the upper model displacement. Using a paired t -test, the null hypothesis tested was that there were no statistical significance differences between the mean distance of the landmarks in the x (medio-lateral), y (anterior–posterior) and z (inferior–superior) directions, on the original model, and on the haptically aligned upper models (SPSS, Chicago, IL; version 20.0).

Fig. 4
Location of the landmarks placed on each of the corners of the upper model base.

Materials and methods

Approval was granted by the Institutional Review Board (IRB) of The University of Hong Kong and Hospital Authority Hong Kong West Cluster (UW11-385) to access this retrospective data, which formed part of a larger cohort study. The orthodontic plaster models were selected from the Faculty of Dentistry, The University of Hong Kong. Only pre-treatment plaster models which could be hand articulated into a single position without any instability e.g. no anterior open bite were included. The correct occlusion had been determined by the inter-occlusal registration or bite that was taken during the clinical examination and record taking session. In total 20 sets of plaster models were selected and the patient hospital numbers recorded. The patient identifier was used to download the corresponding digital models and all images were anonymous and de-identified prior to use.

The digital models had been commercially produced by laser scanning the plaster models using the following process (Modern Dental Laboratory, Cheung Sha Wan, Kowloon, Hong Kong). All dento-alveloar surfaces of the individual upper and lower models were individually scanned together with the full buccal surfaces of the teeth with the models in occlusion (3Shape, Copenhagen, Denmark). The bases of the plaster models had been previous trimmed according to the bite taken at the clinical appointment; this ensured the correct occlusal relationship during scanning. Following scanning the upper and lower models were automatically aligned to the image of the buccal teeth in occlusion (OrthoCAD ® , Cadent, Carlstadt, NJ). New “orthodontically trimmed digital bases” were added to the models. Following scanning, the occlusal contacts of the upper and lower model were assessed using a colour error as well as being visually compared to the original plaster model. The final models were saved as STL files and stored.

Each set of digital study models was imported into VRMesh (VirtualGrid Company, Seattle City, U.S.A.) and decimated by 50% to reduce the number of triangles and enable faster processing ( Fig. 1 A). The original base of the upper model was removed leaving only the teeth and alveolar regions. The lower model was not altered and remained in the same 3D space. The upper model was moved away from the lower model, its orientation changed, ( Fig. 1 B) and then re-saved in its new position in 3D space.

Fig. 1
(A) Final original digital models in occlusion. (B) Upper and lower digital models with virtual bases removed leaving only the teeth and alveolar regions. Removing the bases ensured there were no visible indications for the upper model position.

A prototype system was implemented on a desktop PC with an Intel ® CoreTM i7-3930K CPU and an NVIDIA GeForce GTX 680 display card (Santa Clara, California) connecting the Geomagic ® Touch™ (3D Systems, Rock Hill, South Carolina) haptic device (formerly Sensable Phantom Omni). The Geomagic ® Touch™ provided 6 degrees of freedom (DOF) input and 3DOF force feedback output ( Fig. 2 ). The graphics rendering, and haptic rendering components worked in parallel. The upper dental model was manipulated through the stylus of the haptic device. As haptic interaction is not routine in clinical practice, the operator (BSK) underwent a training session based on fitting 3D shapes into each other using the haptic device. This was followed by haptically aligning 7 training sets of digital models not included in the main study. During the training, once the upper study model was manipulated into the correct position, it turned green. This provided the operator with immediate confirmation of the model position; this function was disabled during the main study.

Fig. 2
Haptic prototype system in use during training session. (A) Pen shaped haptic device (Geomagic ® Touch™ haptic device, formerly Sensable Phantom Omni).

For each set of models, the lower digital model was imported into the prototype system together with the upper model. Using the haptic device the upper model was placed onto the lower model and moved until the operator had a stable occlusion. This was tested by gently moving the haptic device in all three planes of space and feeling resistance i.e. the force feedback indicated the models were “locked” into occlusion. The upper model was then saved in its new 3D space as an STL file.

For each set of digital models, the haptically aligned upper model (teeth and alveolus only), full lower model and the corresponding original upper model were imported into VRMesh. The original upper model was then aligned to the haptically aligned upper model, which remained static. These two models are the same model but the haptically aligned model has no base; the haptically aligned upper model was deleted leaving the original model with base in its new position, this will still be referred to as the haptically aligned model. This model was then saved in STL format ( Fig. 3 ).

Fig. 3
(A) Front view of original digital models in occlusion (grey) and same upper model following haptic alignment (red) with replacement of original virtual base. (B) View from above showing original model (grey) and haptically aligned (red) model bases do not exactly align. (C) Occlusal view of upper model showing original model (grey) and haptically aligned (red) model do not exactly align.(For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)

Operator error

Intra-operator

To determine the intra-operator error 8 sets of models were chosen at random from the original set of 20 models and re-occluded using the 3 DoF haptic system, and re-analysed. The internal consistency of the data for the x , y and z co-ordinates was tested individually using Cronbach’s alpha and the intraclass correlation coefficient (ICC) was used to assess the reproducibility of the method.

Inter-operator

To determine the inter-operator error, 7 additional sets of models were chosen at random and occluded using the 3 DoF haptic system, by a clinician and a non-clinician (student in Computing Science), and analysed. A paired student t -test was used to compare the differences in mean absolute distances of the seven landmarks between the original model and haptically aligned model for the clinician and the non-clinician ( p < 0.05).

Analysis

For each individual, the original upper and lower digital study models were imported in DiView (Dimensional Imaging, Hillington, Glasgow) and 7 landmarks were placed on each of the corners of the upper model base ( Fig. 4 ). The x , y and z co-ordinates of these landmarks were saved. The same individuals haptically aligned upper model, and unaltered lower model, were also imported into DiView. Since they occupied the same 3D space and the lower model had not moved, both lower models were exactly aligned. The same 7 landmarks were placed on each of the corners of the haptically aligned upper model and the x , y and z co-ordinates saved. If the haptically aligned model was in the correct place, both upper models would be perfectly superimposed; any discrepancy in the landmark co-ordinates would provide a measure of the error represented by the upper model displacement. Using a paired t -test, the null hypothesis tested was that there were no statistical significance differences between the mean distance of the landmarks in the x (medio-lateral), y (anterior–posterior) and z (inferior–superior) directions, on the original model, and on the haptically aligned upper models (SPSS, Chicago, IL; version 20.0).

Jun 19, 2018 | Posted by in General Dentistry | Comments Off on A pilot study to assess the feasibility and accuracy of using haptic technology to occlude digital dental models

VIDEdental - Online dental courses

Get VIDEdental app for watching clinical videos