Bioactive glass fillers reduce bacterial penetration into marginal gaps for composite restorations

Highlights

  • Novel bioreactor system was used for in vitro cyclic loading of tooth filling samples.

  • We grew biofilms on simulated tooth restorations with bioactive and control composites.

  • Bacteria penetrated less into marginal gaps for the bioactive glass containing samples.

  • Bioactive glass fillers may have promise for slowing secondary caries formation.

Abstract

Objective

Bioactive glass (BAG) is known to possess antimicrobial and remineralizing properties; however, the use of BAG as a filler for resin based composite restorations to slow recurrent caries has not been studied. Accordingly, the objective of this study was to investigate the effect of adding 15 wt% BAG to a resin composite on bacterial biofilms penetrating into marginal gaps of simulated tooth fillings in vitro during cyclic mechanical loading.

Methods

Human molars were machined into approximately 3 mm thick disks of dentin and 1.5–2 mm deep composite restorations were placed. A narrow 15–20 micrometer wide dentin-composite gap was allowed to form along half of the margin by not applying dental adhesive to that region. Two different 72 wt% filled composites were used, one with 15 wt% BAG filler (15BAG) and the balance silanated strontium glass and one filled with aerosol silica and silanated strontium glass without BAG (0BAG—control). Samples of both groups had Streptococcus mutans biofilms grown on the surface and were tested inside a bioreactor for two weeks while subjected to periods of cyclic mechanical loading. After post-test biofilm viability was confirmed, each specimen was fixed in glutaraldehyde, gram positive stained, mounted in resin and cross-sectioned to reveal the gap profile. Depth of biofilm penetration for 0BAG and 15BAG was quantified as the fraction of gap depth. The data were compared using a Student’s t -test.

Results

The average depth of bacterial penetration into the marginal gap for the 15BAG samples was significantly smaller (∼61%) in comparison to 0BAG, where 100% penetration was observed for all samples with the biofilm penetrating underneath of the restoration in some cases.

Significance

BAG containing resin dental composites reduce biofilm penetration into marginal gaps of simulated tooth restorations. This suggests BAG containing composites may have the potential to slow the development and propagation of secondary tooth decay at restoration margins.

Introduction

The U.S. National Institutes of Health estimates that >122 million composite tooth restorations are placed in the United States annually; however, annual failure rates up to 15% have been reported and a review of the literature suggests the average lifetime of posterior dental composites is only six years . Furthermore, a majority of restorations are replacements of failed restorations . The most common reason for the replacements is secondary caries occurring at the margins . Secondary caries is caused by bacterial microflora and the formation of a biofilm (plaque) at and within the restoration-tooth margin most likely facilitated by a gap forming between the two that allows bacterial colonization . While cyclic loading is a known potential cause of failure for both tooth tissue and restorative materials , margin failure and gap propagation may also occur due to the cyclic loading experienced by restorations during mastication . While resin composites have relatively good adhesive/sealing properties, polymerization shrinkage of the resin during curing imposes stresses on the interface that increase the chance of interfacial failure when combined with cyclic occlusal loading .

While it is known that after successful gap colonization, bacteria consume saccharides and produce lactic acid as the byproduct that demineralizes tooth structure, there is currently a poor understanding of the factors influencing biofilm development and propagation into interfacial gaps. While bacterial biofilm formation is considered a necessary ingredient, a biofilm alone does not guarantee tooth decay . Furthermore, a recent study suggests that cyclic loading plays an important role in aiding biofilm penetration deep into marginal gaps . The decreased pH due to acid production then shifts the equilibrium dissolution reaction of hydroxylapatite toward demineralization with calcium and phosphate ions leaching out of the tissue, causing caries propagation . Streptococcus mutans strains have been identified as the most abundant bacterial species under the restoration in cases of secondary caries . Such findings suggest a strong need for restorative composites with antimicrobial and/or remineralization properties to slow secondary caries formation and extend the life of composite restorations.

Many materials have antimicrobial properties: copper, zinc, silver, various silica-based glasses, etc. . Bioactive glass (BAG) has been shown to have both an antimicrobial effect on oral bacteria and the ability to remineralize adjacent mineralized tissues . The antimicrobial effect of BAG is attributed in part to the release of ions ( e.g. , calcium and phosphate) that have a toxic effect on the bacteria and cause neutralization of the local acidic environment , the latter leads to a local increase in pH that is not well tolerated by many oral bacteria . However, the exact mechanism responsible for the antimicrobial effect of BAG is not completely elucidated.

Although the first BAG was developed more than 40 years ago , exploration into its potential for use in resin based dental restorative composites has only very recently begun . It has been shown that composites containing up to 15% by weight non-silanated BAG filler can have mechanical properties comparable to, or superior to, commercial composites and that the addition of BAG fillers does not compromise the degree of monomer conversion . Furthermore, despite BAG ions leaching out of the composite the degradation of mechanical properties with ageing is no worse, or better than, many commercial composites . Tauböck et al. showed that BAG particles embedded in a resin matrix can still induce bioactivity and increase the pH of a buffered saline solution . Finally, another recent study has looked at doping the BAG with Ag to enahnce its antimicrobial effect .

While it appears clear that BAG-containing composites can meet the mechanical property requirements for dental restorations, there is a need to study the secondary caries resistance of tooth restorations made from BAG-containing composites. Accordingly, the goal of this research was to examine the effect of BAG additions on bacterial biofilm formation along marginal gaps of simulated tooth fillings in vitro . This study will use a previously developed in-vitro testing model that applies cyclic loading to a restored tooth sample while in a living oral bacteria environment . It is hypothesized that BAG-containing composites will have a negative effect on biofilm formation in marginal gaps due to the antimicrobial effects of BAG.

Materials and methods

Bioactive glass composite preparation

BAG filler was produced by the sol–gel process, which was reported in detail previously in . Breifly, pure alkoxides (tetraethyl orthosilicate (TEOS, Si(OC 2 H 5 ) 4 ), calcium methoxyethoxide (CMOE, C 6 H 14 O 4 Ca), and triethyl phosphate (TEP, (C 2 H 5 ) 3 PO 4 )) were used for BAG synthesis. CMOE was synthesized from Ca metal and methoxyethanol, while all other reagents were obtained from Sigma Aldrich. Solutions of the alkoxides in methoxyethanol were prepared in an inert dry nitrogen atmosphere glovebox. The solution was aged, air-dried and then dried at elevated temperatures to evaporate the solvent completely and stabilize the glass. The obtained product was first ball milled, and then processed in a Micronizer jet-mill (Sturtevant Inc., Hanover, MA) to a final fine particle size of 0.04–3 μm. The final composition of the BAG filler used was approximately 65% SiO 2 , 31% CaO and 4% P 2 O 5 (mol%). SEM micrographs of agglomerated BAG filler particles can be seen in Fig. 1 .

Fig. 1
Scanning electron micrograph of the bioactive glass filler used in this study. (a) An agglomerate of BAG particles. (b) A higher magnification view of the BAG particles.

The composite was prepared by combining 57 wt% silanated strontium glass (Bisco Inc.) and 15 wt% BAG with resin matrix containing a 50:50 mixture of bisphenol A glycidyl methacrylate (BisGMA):triethylene glycoldimethacrylate (TEGDMA) monomers with 0.4 wt% of camphorquinone (CQ), 0.8 wt% of 4-dimethylaminobenzoic acid ethyl ether (EDMAB), and 0.05 wt% of 3,5-di-tertbutyl-4-hydroxytoluene (BHT)). The 15% BAG addition was selected based on previous work that demonstrated no significant reduction in mechanical properties when adding up to 15% BAG . The control composite (0BAG), was filled with 5 wt% aerosol silica (OX-50, Degussa) and 67 wt% silanated strontium glass. The 5 wt% silica addition was necessary to achieve adequate handling of the uncured composite. Both composites had a total filler content of 72 wt% and full details on the composite preparation and mechanical properties may be found in .

Sample preparation

Recently extracted human molars were used to produce simulated tooth restoration samples. The complete procedure for sample preparation was described previously in detail in . In brief, the cusps of each molar were sectioned off, and a second section was made across the tooth immediately above the pulp. This sectioning resulted in a disk-shaped slab of tooth ∼2.5–3 mm thick and ∼9 mm in diameter, composed mostly of dentin with some enamel on the circumference. A cavity was machined into the center of each sample 1.5–2 mm deep (to always leave a pulpal floor 1 mm thick) and 5 mm in diameter using a computer controlled milling system (CNC specimen former, U. of Iowa). After machining, the samples were soaked in 1% chloramine T for one week for sterilization. After initial sterilization, the bottom of the cavity and half of its circumference were treated with a dentin bonding agent (Clearfil SE Bond) following the manufacturers instructions. First the primer component was actively applied to the cut dentin surfaces with a disposable micro brush tip for 20 s. Then a mild stream of air was blown on the primer to evaporate volatile components until no observable liquid movement could be detected. Next, the bonding component was applied to all primed surfaces with a disposable micro brush tip, then brush thinned with a separate disposable brush tip to ensure a uniform thickness of the adhesive layer. The bonding agent was cured for 10 s using a Kerr Demetron Demi light curing unit with an approximate 1000 mW/cm 2 irradiance. Finally, the composite was inserted in a single increment (max thickness of 2 mm) and cured for 20 s with the same light curing unit.

Due to polymerization shrinkage, a ∼15–20 μm gap was formed around approximately half of the circumference where the dentin bonding agent was not originally applied. A 1 mm thick shim was used to protect the half of the circumference where the gaps were created ( Fig. 2 ). The composite surface of the sample was polished with fine abrasive disks (Sof-flex, 3M ESPE) to reveal the cavosurface margin and the gap. The samples were sterilized in 70% ethanol for 1 h and placed in sterile brain heart infusion (BHI) media for storage, thus allowing ethanol to diffuse out of the specimen and to check for successful sterilization. Six ( N = 6) 15BAG and six ( N = 6) 0BAG samples were prepared.

Fig. 2
Sample during adhesive application with the 1 mm thick shim in place.

Biofilms were grown on each sample by incubating at 37 °C in 5% CO 2 and 95% relative humidity (BBD 6220 incubator, Thermo, Asheville, NC, USA) in separate petri dishes with approximately 15 ml of initially sterilized BHI media with 3% sucrose. One milliliter of S. mutans bacteria culture at an optical density of 0.8 was added to each dish. Incubation lasted approximately 4 days and the media was refreshed each day, until the biofilm could be observed with a naked eye. The samples were then placed in sterile bioreactors for further testing.

Test method

A novel bioreactor capable of in-situ cyclic loading was used for the demineralization studies ( Fig. 3 ), and has been described previously in full detail . Samples were placed in the bioreactor composite side down on top of a 7 mm diameter ring shaped stand ( Fig. 3 a). A combined biaxial bending and shear loading was applied by a semispherical ended loading rod (3 mm diameter) at the center of the sample which was aligned and fixed in the center of the bioreactor by a linear bearing in the top cover ( Fig. 3 a and b). When assembled, the entire bioreactor was completely sealed using rubber seals. Previous testing with these bioreactors demonstrated no external contamination over the entire two week experiment time . Three specimens were tested simultaneously using three separate bioreactors ( Fig. 3 c). During the experiments, incubator conditions (see above) were reproduced inside each bioreactor. Fresh sterilized BHI media was pumped into the lower pipe fitting (fluid inlet in Fig. 3 b) of the bioreactor at approximately 1 ml/min flow rate and pumped out of the test cell at the level just above the sample through the outlet pipe fitting to ensure the media covered the entire sample. Fluid motion was produced with peristaltic pumps (Model FB 70381, Thermo Fischer Scientific Inc., Waltham, MA, USA) at both the inlet and outlet. A 5% CO 2 -air mixture was flowed through a 0.2 μm syringe filter into each bioreactor at a low flow rate to just maintain visible bubbles at the outlet. Each bioreactor was submerged to roughly half of its height in a 37 °C water bath controlled by a digital immersion circulator (Cole-Palmer, Vernon Hills, IL, USA).

Fig. 3
(a) Sample schematic and relative position of sample, sample stand ring support and loading rod. (b) Detailed assembly of a bioreactor test cell. (c) Schematic of the test setup for loading three samples at a time.
Figure reproduced from with permission from Elsevier.

Cyclic loading was applied using a computer controlled servo-hydraulic test system (Model 8872, Instron Corporation, Norwood, MA, USA). Fig. 3 c shows how the load was equally distributed between three bioreactors using a ball bearing interface. The load for each specimen was measured using individual load cells (Model LCF300, FUTEK Advanced Sensor Technology Inc., Irvine, CA, USA), with the difference between each cell load always <5%. Specimen loading was done by alternating blocks of cyclic loading and resting periods. Cyclic loading blocks were 2 h of cycling with the maximum load of ∼113 N and a minimum load of ∼11.3 N which corresponds to 25% and 2.5%, respectively, of the measured mean breaking force (450 N). During the resting periods, samples were kept at the minimum (11.3 N) load for 4 h. The two block sequence was repeated 56 times to give a total of time of ∼2 weeks for each experiment.

After each experiment, the samples were removed from the bioreactors and were subjected to a live/dead staining procedure (Life Technologies Live/Dead BacLight Bacterial Viability Kit) following the kit manufacture’s protocol and the biofilm was evaluated under confocal laser scanning microscopy (CSLM) to ensure the biofilm was still viable at the end of the experiments. Once biofilm viability was confirmed the samples were fixed in 10 ml 4%-gluteraldehyde and held at a temperature of 4 °C overnight.

For gap analysis the biofilm was carefully removed from the surface with a swab, avoiding the gap area. The specimens were gram positive stained by applying crystal violet dye (Difco Laboratories, Detroit MI, USA), rinsing, and applying iodine to bind the dye to the bacteria. Samples were then mounted in LR white resin (London Resin Company Ltd, Reading, Berkshire England), sectioned in half on a slow speed diamond saw, and finally examined under the stereomicroscope for the presence of dentin demineralization and the extent of penetration of the stained bacterial biofilm. The sample half with the greatest apparent demineralization from the stereomicroscopic evaluation was further examined with CSLM (BioRad/Zeiss Radiance 2100 confocal laser scanning system) using 4×/0.2 objective. An ion Argon laser source with excitation at 488 nm and a 500–550 nm band pass filter was used to detect the autofluorescence while a GRE/Ne laser source with excitation band at 543 nm wavelength and a 570 nm long pass filter was used to detect the stained bacteria in the biofilm. Demineralization of the dentin was revealed by the autofluorescence as bright green and the presence of the biofilm was revealed by the gram stain as red. Since dentin is naturally fluorescent, demineralization was correlated to the brightest green autofluorescence regions by Knoop micro-hardness mapping (Duramin 5 hardness tester, Struers Inc., Cleveland, OH, USA). A 100 gf load was used with a 20 s dwell time and the imprint sizes were measured using optical microscopy. ImageJ (U. S. National Institutes of Health, Bethesda, Maryland, USA) was used to assess gap sizes and bacterial penetration, the latter of which was quantified as a fraction of the total depth of the gap and a Student’s t -test ( α ≤ 0.05) was used to compare the 0BAG and 15BAG cases.

Materials and methods

Bioactive glass composite preparation

BAG filler was produced by the sol–gel process, which was reported in detail previously in . Breifly, pure alkoxides (tetraethyl orthosilicate (TEOS, Si(OC 2 H 5 ) 4 ), calcium methoxyethoxide (CMOE, C 6 H 14 O 4 Ca), and triethyl phosphate (TEP, (C 2 H 5 ) 3 PO 4 )) were used for BAG synthesis. CMOE was synthesized from Ca metal and methoxyethanol, while all other reagents were obtained from Sigma Aldrich. Solutions of the alkoxides in methoxyethanol were prepared in an inert dry nitrogen atmosphere glovebox. The solution was aged, air-dried and then dried at elevated temperatures to evaporate the solvent completely and stabilize the glass. The obtained product was first ball milled, and then processed in a Micronizer jet-mill (Sturtevant Inc., Hanover, MA) to a final fine particle size of 0.04–3 μm. The final composition of the BAG filler used was approximately 65% SiO 2 , 31% CaO and 4% P 2 O 5 (mol%). SEM micrographs of agglomerated BAG filler particles can be seen in Fig. 1 .

Fig. 1
Scanning electron micrograph of the bioactive glass filler used in this study. (a) An agglomerate of BAG particles. (b) A higher magnification view of the BAG particles.

The composite was prepared by combining 57 wt% silanated strontium glass (Bisco Inc.) and 15 wt% BAG with resin matrix containing a 50:50 mixture of bisphenol A glycidyl methacrylate (BisGMA):triethylene glycoldimethacrylate (TEGDMA) monomers with 0.4 wt% of camphorquinone (CQ), 0.8 wt% of 4-dimethylaminobenzoic acid ethyl ether (EDMAB), and 0.05 wt% of 3,5-di-tertbutyl-4-hydroxytoluene (BHT)). The 15% BAG addition was selected based on previous work that demonstrated no significant reduction in mechanical properties when adding up to 15% BAG . The control composite (0BAG), was filled with 5 wt% aerosol silica (OX-50, Degussa) and 67 wt% silanated strontium glass. The 5 wt% silica addition was necessary to achieve adequate handling of the uncured composite. Both composites had a total filler content of 72 wt% and full details on the composite preparation and mechanical properties may be found in .

Sample preparation

Recently extracted human molars were used to produce simulated tooth restoration samples. The complete procedure for sample preparation was described previously in detail in . In brief, the cusps of each molar were sectioned off, and a second section was made across the tooth immediately above the pulp. This sectioning resulted in a disk-shaped slab of tooth ∼2.5–3 mm thick and ∼9 mm in diameter, composed mostly of dentin with some enamel on the circumference. A cavity was machined into the center of each sample 1.5–2 mm deep (to always leave a pulpal floor 1 mm thick) and 5 mm in diameter using a computer controlled milling system (CNC specimen former, U. of Iowa). After machining, the samples were soaked in 1% chloramine T for one week for sterilization. After initial sterilization, the bottom of the cavity and half of its circumference were treated with a dentin bonding agent (Clearfil SE Bond) following the manufacturers instructions. First the primer component was actively applied to the cut dentin surfaces with a disposable micro brush tip for 20 s. Then a mild stream of air was blown on the primer to evaporate volatile components until no observable liquid movement could be detected. Next, the bonding component was applied to all primed surfaces with a disposable micro brush tip, then brush thinned with a separate disposable brush tip to ensure a uniform thickness of the adhesive layer. The bonding agent was cured for 10 s using a Kerr Demetron Demi light curing unit with an approximate 1000 mW/cm 2 irradiance. Finally, the composite was inserted in a single increment (max thickness of 2 mm) and cured for 20 s with the same light curing unit.

Due to polymerization shrinkage, a ∼15–20 μm gap was formed around approximately half of the circumference where the dentin bonding agent was not originally applied. A 1 mm thick shim was used to protect the half of the circumference where the gaps were created ( Fig. 2 ). The composite surface of the sample was polished with fine abrasive disks (Sof-flex, 3M ESPE) to reveal the cavosurface margin and the gap. The samples were sterilized in 70% ethanol for 1 h and placed in sterile brain heart infusion (BHI) media for storage, thus allowing ethanol to diffuse out of the specimen and to check for successful sterilization. Six ( N = 6) 15BAG and six ( N = 6) 0BAG samples were prepared.