Reliability of computer designed surgical guides in six implant rehabilitations with two years follow-up

Abstract

Objective

To evaluate the reliability and accuracy of computer-designed surgical guides in osseointegrated oral implant rehabilitation.

Materials and methods

Six implant rehabilitations, with a total of 17 implants, were completed with computer-designed surgical guides, performed with the master model developed by muco-compressive and muco-static impressions. In the first case, the surgical guide had exclusively mucosal support, in the second case exclusively dental support. For all six cases computer-aided surgical planning was performed by virtual analyses with 3D models obtained by dental scan DICOM data.

The accuracy and stability of implant osseointegration over two years post surgery was then evaluated with clinical and radiographic examinations. Radiographic examination, performed with digital acquisitions (RVG – Radio Video graph) and parallel techniques, allowed two-dimensional feedback with a margin of linear error of 10%.

Results

Implant osseointegration was recorded for all the examined rehabilitations. During the clinical and radiographic post-surgical assessments, over the following two years, the peri-implant bone level was found to be stable and without appearance of any complications. The margin of error recorded between pre-operative positions assigned by virtual analysis and the post-surgical digital radiographic observations was as low as 0.2 mm.

Significance

Computer-guided implant surgery can be very effective in oral rehabilitations, providing an opportunity for the surgeon: (a) to avoid the necessity of muco-periosteal detachments and then (b) to perform minimally invasive interventions, whenever appropriate, with a flapless approach.

Introduction

Oral rehabilitation supported by osseointegrated implants now represents a valuable therapeutic strategy both from an esthetic and a functional point of view . In oral rehabilitation with a traditional surgical approach using osseointegrated implants, the surgeon is often obliged to perform essential muco-periosteal detachments in order to obtain good visibility of the bone structures. Indeed the later intraoperative stages cannot be properly viewed if a flapless approach is used, which, although valid from a point of view of implant osseointegration , significantly increases the margins of imprecision and the possibility of failure if not performed with a guided technique.

Muco-periosteal detachments turn out to be much more extended when the number of implants to be placed increases and this may result in significant implant mobility for the patient. Furthermore, if strategic positioning of implant inclined fixtures, mesially or distally, is required, compared to anatomically relevant structures, the operator is forced to invade the maxillary sinus in order to highlight the margins – or, alternatively, to highlight the emerging part of the inferior alveolar nerve from the mental foramen in the case of a procedure on the mandible.

Intra-operative visibility is important especially if bone structures have been preoperatively evaluated only with the aid of two-dimensional radiographic investigations, such as standard radiographs or intraoral orthopantomographies. These last two procedures, however, expose the patient to a low radiation dosage . More information about the quality, quantity and bone topography can be obtained preoperatively with the aid of survey systems such as three-dimensional CT (Computed Tomography) and Cone Beam CT (CBCT) systems .

The data coming from these examinations, however, must be analyzed with the aid of dedicated software. This allows a very detailed interpretation and therefore significantly increases the pre-operative information available to the implant surgeon. In particular, if three-dimensional radiographic investigations are conducted with radiological intraoral guides, developed by previous diagnostic waxing, it is then possible to place the implants by virtual simulations with computer-aided planning.

The aims of this work were to reduce the time required for surgery, to increase the accuracy of the implant positioning using a flapless approach, or in any case one that is minimally invasive, and at the same time to improve the post-operative treatment of the patient through the use of computer-designed surgical guides, developed with a combination of virtual models and mechanical systems. By using these it is possible to input and transfer the correct three-dimensional implant coordinates from the virtual planning stage to the master model in the prosthodontic laboratory.

Materials and methods

Six patients were selected with different implant-prosthetic rehabilitative requirements. Three patients had a single unilateral intercalated edentulous dentition and to preserve the soft peri-implant tissue, one of these three rehabilitations was performed with a flapless approach. One patient exhibited a non-intercalated unilateral distal edentulous dentition, and was rehabilitated with two implant fixtures using a flapless approach and a temporary immediate load. Two patients exhibited a total maxillary edentulous dentition, and were rehabilitated with six implants via a flapless approach and temporary immediate load. In the latter case the surgical guide was used for exclusive mucosal support. Moreover, in both total maxillary edentulous dentitions, bone-residual implants were lodged in a strategically inclined way to reduce the distal cantilever and consequently to reduce the stress to which these systems are subjected . The distribution of the implant sites is shown in Table 1 .

Table 1
Patients and distribution of the implant sites.
Patient 1 Patient 2 Patient 3 Patient 4 Patient 5 Patient 6
36 46 16 45–46 16–14–12–22–24–26 16–14–12–22–24–26

Inclusion criteria for this study were:

  • The absence of any relevant systemic diseases that would contraindicate osseointegrated implant rehabilitation.

  • The presence of sufficient bone volume for the placement of implant fixtures without using regenerative techniques.

  • In the case of smokers, no more than 10 cigarettes for day.

Radiographic stents

Virtual surgical planning was achieved using softwareIMPLANT 3D by Medialab. By this means, it was possible to examine in minute detail the bony structures and the mucous profiles of the patient to evaluate the positioning of implant fixtures in a prosthetically guided manner. In respect of hard and soft tissues, it was possible to evaluate the remaining portion of hard and soft tissues after virtual positioning the implant before surgery. This planning was possible through the interpretation of DICOM images of the dental examination-scan carried out on the patient with radiographic stents suitably positioned and supported in the oral cavity. The radiography stents were produced from self-curing resin mixed with barium sulfate powder in a ratio of 3:1.

To avoid unwanted cuspal overlaps of opposing teeth and to effectively stabilize the radiographic stents during the CT examination, some stabilizers were made using extra-hard wax of 10 mm height, which patients bit occlusally between their dental arches during CT examination ( Fig. 1 ).

Fig. 1
Occlusal check in extra-hard wax during CT examination.

The radiographic stents constituted an important landmark to correct the diagnosis in the virtual analysis. They were developed by our dental technician using suitable diagnostic wax, in turn developed from previous esthetic analysis. In this way it was possible to achieve 3D virtual simulations, with implant planning, not only in a prosthetically guided way, but especially in a manner that was biomechanically correct ( Fig. 2 ).

Fig. 2
Implant planning by 3D virtual simulations.

Impression techniques

Special care was taken to select reliable impressions and an extremely precise protocol for the support of future surgical stents. In the case of surgical stents for dental support, the impression had a mucostatic character and was performed with a one-step, two-phase technique.

The materials used for mucostatic impressions were PVS addition silicones (Poly Vinyl Siloxanes) used in the following manner. The first phase of the material (Express II, 3M) was placed exclusively in the tray while the second phase (Extrude regular, KERR) was injected only within the patient’s oral cavity ( Fig. 3 ).

Fig. 3
Mucostatic impression for surgical stents with dental support.

In the case of surgical stents for exclusive mucosal support, the impressions were taken with an overextended muco-compressive character ( Fig. 4 ). Alternatively, to suppress mucosal resilience in total edentulous cases, and therefore to increase the stability and the fidelity of future surgical guides with exclusive mucosal support, a biphasic impression was created in two stages.

Fig. 4
Muco-compressive impressions for surgical stents with exclusive mucosal support.

Again, in such cases, the materials used were PVS A-silicones. For the first phase, a silicone putty-dough of heavy consistency (Extrude heavy body, KERR) was used. For the second phase a medium consistency silicone (Extrude regular, KERR) was used. This was not injected directly into the oral cavity, but placed exclusively in the tray above the heavy stage, without having previously altered the impression, as normally happens in the putty-wash technique.

This type of procedure was adopted to avoid the necessity of having to use an intra-bone anchor-pin during the surgical procedure, for optimum stability of the surgical stents, when using only the mucosal support. The reason for reducing the resilience of the mucosal part was so that it would not generate a considerable margin of error.

Surgical stents

Surgical stents were fabricated using a Ray Set machine (Biaggini Medical Devices) ( Fig. 5 ). By this it was possible to interpret the 3D data obtained from the virtual planning stage. From the virtual data, the implant coordinates were transferred to the Ray Set machine. The machine orientated the resin or plaster master model and then placed, in a correct three-dimensional manner, the implant analogs in accordance with the parameters from the virtual analysis.

Fig. 5
Ray set machine.

Once correctly positioned in the master model, the analog implants were superimposed on the mirror-like image from virtual preoperative planning. The dental technician could then make both surgical stents with a resinous framework like total removal dentures (see stents for exclusive mucosal support), and surgical stents with a metal core like a skeleton (see stents at the exclusive dental support).

An important aspect was the possibility of making customizations at the surgeon’s request where, for periodontal reasons, it may be convenient to support and protect the access flaps ( Fig. 6 ).

Fig. 6
Customizations to support and protect the access flaps.

Surgical and prosthetic protocol

Seventeen conical implants were used with lengths between 11 and 13 mm (EXACTA WP, Biaggini Medical Devices), to obtain the best primary stability possible, which however was always above 45 N.

For the same reason, the implant sites on the upper jaw were all under-prepared. On the basis of periodontal biotype a flapless approach was chosen. In the case of a thick biotype, and an approach with flap in the case of thin biotype, in order to preserve the keratinized gingiva.

The number of implants, the length and type of surgical approaches, are summarized in Table 2 .

Table 2
Number and length of implants and type of surgical approach.
Flapless With flap
Implant length 11 mm 4 1
Implant length 13 mm 11 1

All implants received the provisional immediate load within 48 h post-surgery. In the case of the individual intercalated edentulous patients the prosthesis was attached through the abutment millable prosthesis screwed with a torque of 30 N cm, and using a cemented resin crown. The undisputed advantage of being able to use a presurgical master model was the possibility for the clinician to have a provisional prosthetic device immediately after surgery, substantially shortening the time before prosthetic loading.

In the case of total edentulism a provisional immediate load with screwed metal mesostructure and resin superstructure was used, after having taken a suitable master impression immediately after surgery ( Fig. 7 ).

Fig. 7
Master impression immediately after surgery in the case of total edentulism.

The taking of the master post-surgical impressions was greatly facilitated by the prosthetic planning performed on the master pre-surgical model. By this means it was possible to prepare the splinting resin, the individual tray ( Fig. 8 ) and even the prosthetic pre-angular components (EXE WP, Biaggini Medical Devices) able to compensate and correct for the implant dis-parallelism ( Fig. 9 ).

Fig. 8
Prosthetic planning performed on the master presurgical model: splinting resin, individual spoon.

Fig. 9
Prosthetic preangular components on the master presurgical model able to compensate and correct for the implant dis-parallelism.

Post-operative radiographs and follow up

Immediately after surgery and two years after surgery, control intraoral radiographs were made, to superimpose and compare, in the virtual environment, linear measurements obtained from the digital postoperative radiographs.

These radiographs were acquired on-line by computer with the digital sensor (RVG, Trophy). Thereby it was possible to obtain two-dimensional feedback with a margin of error of 9% . However, for verification of this percentage, it was essential to adopt the parallel technique, according to which the digital sensor and the dental element, namely the implant to be radiographed must be positioned perpendicularly to the axis of the X-ray tube.

Concurrently with the digital radiographic examinations, starting from three months after surgery, clinical examinations were performed designed to highlight any peri-implant problems, such as lack of osseointegration in the first place, and secondly, any peri-implantitis with loss of peri-implant bone support.